[x] Welcome at THunting.com!

A fun place to talk about Metal Detecting, Treasure Hunting & Prospecting. Here you can share finds and experience with thousands of members from all over the world

Join us and Register Now - Its FREE & EASY

THunting.com
Treasure Hunting & Metal Detecting Community
   
Advanced Search
*
Welcome, Guest! Please login or register HERE - It is FREE and easy.
Only registered users can post and view images on our message boards.
Did you miss your activation email?

Login with email, password and session length
Or Login Using Social Network Account
2
News:
Pages:  1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 ... 35   Go Down
Print
Share this topic on FacebookShare this topic on Del.icio.usShare this topic on DiggShare this topic on RedditShare this topic on Twitter
Tags:
0 Members and 1 Guest are viewing this topic.
Offline xavier
Platin Member
*

From a rainy Brussels
Join Date: May, 2009
Thank you166

Activity
0%
Male
Belgium
Posts: 7339
Referrals: 0

32206.00 Gold
View Inventory

Awards
« Reply #100 on: December 27, 2010, 02:53:46 pm »
Go Up Go Down

Dany475 when adjusting your machine you must do it at the ground level that you are going to use it there is no point in adjusting it at 50cm from the ground if you're going to sweep at 5cm.

Linkback:

You are not allowed to view links.
Please Register or Login

http://www.thunting.com/smf/index.php/topic,17174.msg133838.html#msg133838


Xavier


Logged

So many questions so little time

Offline danny475
Copper Member
*

dont go away when you hunt a expansive thing
Join Date: Jul, 2010
Thank you0

Activity
0%
Male
Syrian Arab Republic
Posts: 82
Referrals: 0

530.00 Gold
View Inventory

Awards
« Reply #101 on: December 27, 2010, 03:48:15 pm »
Go Up Go Down

thanks ram
thanks xavier
i will try the two options and post the result
thanks

Linkback:

You are not allowed to view links.
Please Register or Login

http://www.thunting.com/smf/index.php/topic,17174.msg133854.html#msg133854




Logged
Offline mietekgil
Pull Tab
*

Join Date: Jan, 2011
Thank you1

Activity
0%

Poland
Posts: 9
Referrals: 0

40.00 Gold
View Inventory

Awards

f75
« Reply #102 on: January 08, 2011, 10:13:22 am »
Go Up Go Down

Hello everyone. I would like to build a pim-1 from first posts and I have a few questions. Is this a good detector? Is better to build a DP with 2x16 LCD? In my country 74hvc4066 is not available, but I have 74hc4066 - if I can use this, it will be ok?
 Does the code included for 4x20 lcd language is English or Turkish? On youtube I saw a Turkish language and if I can change it to English? What does the panel shortcuts BL, S, E +, E-etc? Sorry for so many questions, but have not found the answer in the forum. Greetings to all and thank you for your help.


Linkback:

You are not allowed to view links.
Please Register or Login

http://www.thunting.com/smf/index.php/topic,17174.msg136293.html#msg136293




« Last Edit: January 08, 2011, 10:47:30 am by mietekgil »
Logged
Offline freedan3d
Copper Member
*

Join Date: Nov, 2010
Thank you11

Activity
0%

Iran, Islamic Republic of
Posts: 29
Referrals: 0

155.00 Gold
View Inventory

Awards

pulse 2
« Reply #103 on: January 08, 2011, 03:32:43 pm »
Go Up Go Down

I started that PIM-1 about 1 week ago. Cool
But i cant find 74vhc4046 too . Its 4046 its not 4066 !!! No no!
I find MN4046B and in my mind its not different. Wise
I cant find NE5534 in my location. Cry

When i compelete it , i'll send any pic and film to you .

Best regards
Freedan3D

Linkback:

You are not allowed to view links.
Please Register or Login

http://www.thunting.com/smf/index.php/topic,17174.msg136334.html#msg136334



There are 3 attachment(s) in this post which you can not view or download

Please register for viewing them.

4046.pdf
74VHC4046.pdf
PIM.jpg


Logged
Offline mietekgil
Pull Tab
*

Join Date: Jan, 2011
Thank you1

Activity
0%

Poland
Posts: 9
Referrals: 0

40.00 Gold
View Inventory

Awards

f75
« Reply #104 on: January 09, 2011, 05:00:58 am »
Go Up Go Down

Quote:Posted by freedan3d
Its 4046 its not 4066


Welcome freedan3d. Of course, I meant about 4046 - my mistake in writing. As for 74vhc4046 - looks the same. I found (mm or mc) 74hc4046 - parameters and pinouts are the same. You can also find a series of 74hct4046 and schs204a (cd74hc4046). For ne5534 you can check the TL071 and OPA134 (but I'm not sure at 100%).
Regards, Mietekgil.

Posted on: January 09, 2011, 03:32:42 AM
NE5534 = NJM5534. Maybe you can find this item.
 Regards,
 Mietekgil

Linkback:

You are not allowed to view links.
Please Register or Login

http://www.thunting.com/smf/index.php/topic,17174.msg136474.html#msg136474



There are 7 attachment(s) in this post which you can not view or download

Please register for viewing them.

ae04059.pdf
mc74hc4046a-d.pdf
mm74hc4046.pdf
ne5534-d.pdf
opa134.pdf
schs204a.pdf
slos080d.pdf


Logged
Offline ramTopic starter
Silver Member
*

Join Date: Jul, 2007
Thank you148

Activity
0%

Portugal
Posts: 814
Referrals: 0

5270.00 Gold
View Inventory

Awards
« Reply #105 on: January 09, 2011, 09:32:01 am »
Go Up Go Down

Quote:Posted by freedan3d
started that PIM-1 about 1 week ago.
But i cant find 74vhc4046 too . Its 4046 its not 4066 !!!
I find MN4046B and in my mind its not different.
I cant find NE5534 in my location.

freedan3d, if pim1 is finished pls post the performance data of pim1.

ram,
When i compelete it , i'll send any pic and film to you .

Best regards
Freedan3D



Linkback:

You are not allowed to view links.
Please Register or Login

http://www.thunting.com/smf/index.php/topic,17174.msg136511.html#msg136511




Logged
Offline mietekgil
Pull Tab
*

Join Date: Jan, 2011
Thank you1

Activity
0%

Poland
Posts: 9
Referrals: 0

40.00 Gold
View Inventory

Awards

f75
« Reply #106 on: January 09, 2011, 12:43:29 pm »
Go Up Go Down

Hello ram,
Please tell me what the abbreviations on the panel
BL, S, E +, E-, etc?

Linkback:

You are not allowed to view links.
Please Register or Login

http://www.thunting.com/smf/index.php/topic,17174.msg136540.html#msg136540




Logged
Offline xavier
Platin Member
*

From a rainy Brussels
Join Date: May, 2009
Thank you166

Activity
0%
Male
Belgium
Posts: 7339
Referrals: 0

32206.00 Gold
View Inventory

Awards
« Reply #107 on: January 09, 2011, 02:06:45 pm »
Go Up Go Down

Hi mietekgil

Pin 1 GND = GROUND
Pin 2 VCC = POWER
Pin 3 VO Contrast addjust
Pin 4 RS Register select
Pin 5 R/W Read write
Pin 6 E Clock enable
Pin 7 D0 Not used in 4 bit
Pin 8 D1        "
Pin 9 D2        "
Pin 10 D3       "
Pin 11 D4 bit 4
Pin 12 D5 bit 5
Pin 13 D6 bit 6
Pin 14 D7 bit 7
Pin 15 BL = Back light
Pin 16 BL = Back light Pos or neg depending on colour that you want ( green or yellow)

Regards Xavier

Linkback:

You are not allowed to view links.
Please Register or Login

http://www.thunting.com/smf/index.php/topic,17174.msg136557.html#msg136557


Xavier


Logged

So many questions so little time

Offline freedan3d
Copper Member
*

Join Date: Nov, 2010
Thank you11

Activity
0%

Iran, Islamic Republic of
Posts: 29
Referrals: 0

155.00 Gold
View Inventory

Awards

pulse 2
« Reply #108 on: January 09, 2011, 03:00:18 pm »
Go Up Go Down

Hi xavier
Thanks for you information
But mietekgil purpose is front panel buttons

So, what is the best coil for this MD? What is the measure of coil?is it 400 uh?
I have a self-meter device and haven't any problem to make it whit any wires.

regards
Freedan3d

Linkback:

You are not allowed to view links.
Please Register or Login

http://www.thunting.com/smf/index.php/topic,17174.msg136589.html#msg136589




Logged
Offline xavier
Platin Member
*

From a rainy Brussels
Join Date: May, 2009
Thank you166

Activity
0%
Male
Belgium
Posts: 7339
Referrals: 0

32206.00 Gold
View Inventory

Awards
« Reply #109 on: January 09, 2011, 03:09:57 pm »
Go Up Go Down

He he guess that I gave him the wrong info then  Grin

Regards Xavier

Linkback:

You are not allowed to view links.
Please Register or Login

http://www.thunting.com/smf/index.php/topic,17174.msg136592.html#msg136592


Xavier


Logged

So many questions so little time

Print
Pages:  1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 ... 35   Go Up
Jump to:  

Powered by SMF 1.1.19 | SMF © 2005, Simple Machines | Sitemap
Copyright THunting.com