[x] Welcome at THunting.com!

A fun place to talk about Metal Detecting, Treasure Hunting & Prospecting. Here you can share finds and experience with thousands of members from all over the world

Join us and Register Now - Its FREE & EASY

THunting.com
Treasure Hunting & Metal Detecting Community
   
Advanced Search
*
Welcome, Guest! Please login or register HERE - It is FREE and easy.
Only registered users can post and view images on our message boards.
Did you miss your activation email?

Login with email, password and session length
Or Login Using Social Network Account
News:
Pages:  1 ... 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 ... 91   Go Down
Print
Share this topic on FacebookShare this topic on Del.icio.usShare this topic on DiggShare this topic on RedditShare this topic on Twitter
Tags:
0 Members and 1 Guest are viewing this topic.
Offline ehsanajal
Copper Member
*

Join Date: Nov, 2010
Thank you1

Activity
0%

Afghanistan
Posts: 26
Referrals: 0

140.00 Gold
View Inventory
Windows NT 6.3
Windows NT 6.3
Firefox 36.0
Firefox 36.0

Awards
« Reply #690 on: March 15, 2015, 02:18:54 pm »
Go Up Go Down

Quote:Posted by cool2010
first look at the data sheets for 16f676 and 18f252 i added at the bottom youll see not same  ...youll see i added shema for dp2 used 18f252 for LCD ... and look DP using 16f676 for LCD not same you must to change your shema and code for 252  for DP ...

hi i know diff.but any body hack it and put here to use.because 200 times very low.
regards

Linkback:

You are not allowed to view links.
Please Register or Login

http://www.thunting.com/smf/index.php/topic,28024.msg293529.html#msg293529




Logged
Offline cool2010
Bronze Member
*

Mood:Sleepy
Sleepy

Bad boy :D
Join Date: Oct, 2010
Thank you32

Activity
0%

United Kingdom
Posts: 169
Referrals: 0

865.00 Gold
View Inventory
Windows NT 6.3
Windows NT 6.3
Chrome 40.0.2214.115
Chrome 40.0.2214.115

Awards
« Reply #691 on: March 15, 2015, 02:24:06 pm »
Go Up Go Down

what 200 times to low ?

Linkback:

You are not allowed to view links.
Please Register or Login

http://www.thunting.com/smf/index.php/topic,28024.msg293530.html#msg293530




Logged
Offline ehsanajal
Copper Member
*

Join Date: Nov, 2010
Thank you1

Activity
0%

Afghanistan
Posts: 26
Referrals: 0

140.00 Gold
View Inventory
Windows NT 6.3
Windows NT 6.3
Firefox 36.0
Firefox 36.0

Awards
« Reply #692 on: March 15, 2015, 02:31:29 pm »
Go Up Go Down

Quote:Posted by cool2010
what 200 times to low ?

sorry.my means 200 times is demo hex file and after on/off it should reprogram .

now new question:
which coil better. make by AL or CU or AG for dp?

Linkback:

You are not allowed to view links.
Please Register or Login

http://www.thunting.com/smf/index.php/topic,28024.msg293531.html#msg293531




Logged
Offline cool2010
Bronze Member
*

Mood:Sleepy
Sleepy

Bad boy :D
Join Date: Oct, 2010
Thank you32

Activity
0%

United Kingdom
Posts: 169
Referrals: 0

865.00 Gold
View Inventory
Windows NT 6.3
Windows NT 6.3
Chrome 40.0.2214.115
Chrome 40.0.2214.115

Awards
« Reply #693 on: March 15, 2015, 02:51:13 pm »
Go Up Go Down

The intensity of the magnetic field affects the earth's depths. this is proportional to the current intensity , the wire diameter and number of turns.  Wink
you must to do according to your requirement of your detector's tx or ..x The value of inductance...

i added huge coils at the bottom  Grin

Linkback:

You are not allowed to view links.
Please Register or Login

http://www.thunting.com/smf/index.php/topic,28024.msg293535.html#msg293535



There are 4 attachment(s) in this post which you can not view or download

Please register for viewing them.

3.jpg
IMG_7904-1.jpg
frame.JPG
ramka_.jpg


« Last Edit: March 15, 2015, 03:33:19 pm by cool2010 »
Logged
Offline nickel_n
Mod
Gold Member
*****

Join Date: Jan, 2009
Thank you356

Activity
5%
Male
Australia
Posts: 2769
Referrals: 0

6065.00 Gold
View Inventory
Windows XP
Windows XP
Firefox 36.0
Firefox 36.0

Awards

MXT All Pro,EagleSL,Spectrum,XLT,DFX.Garrett Seahunter markII,SD2000,GT16000
« Reply #694 on: March 15, 2015, 03:34:53 pm »
Go Up Go Down

Quote:Posted by ehsanajal
any body hack it and put here to use

On this forum we do NOT HACK intellectual property and we don’t post it without permission.
Please DO NOT ASK again


Linkback:

You are not allowed to view links.
Please Register or Login

http://www.thunting.com/smf/index.php/topic,28024.msg293536.html#msg293536




Logged

The Diggers Oath
We swear by the Southern Cross to stand by each other and fight to defend our rights and liberties.

Offline ehsanajal
Copper Member
*

Join Date: Nov, 2010
Thank you1

Activity
0%

Afghanistan
Posts: 26
Referrals: 0

140.00 Gold
View Inventory
Windows NT 6.3
Windows NT 6.3
Firefox 36.0
Firefox 36.0

Awards
« Reply #695 on: March 30, 2015, 05:24:11 am »
Go Up Go Down

i buy 18f252.how i adjust it?is it good for all coil?

Linkback:

You are not allowed to view links.
Please Register or Login

http://www.thunting.com/smf/index.php/topic,28024.msg294298.html#msg294298




Logged
Offline RAMPI
Copper Member
*

Join Date: Jun, 2013
Thank you43

Activity
0%

Philippines
Posts: 87
Referrals: 0

877.00 Gold
View Inventory
Windows 7/Server 2008 R2
Windows 7/Server 2008 R2
Firefox 33.0
Firefox 33.0

Awards

Pulse Induction Metal detector
« Reply #696 on: March 31, 2015, 08:00:00 am »
Go Up Go Down

My new DP2..

Linkback:

You are not allowed to view links.
Please Register or Login

http://www.thunting.com/smf/index.php/topic,28024.msg294333.html#msg294333



There are 2 attachment(s) in this post which you can not view or download

Please register for viewing them.

IMG_20130106_193038.jpg
IMG_20130106_193051.jpg


Logged
Offline ehsanajal
Copper Member
*

Join Date: Nov, 2010
Thank you1

Activity
0%

Afghanistan
Posts: 26
Referrals: 0

140.00 Gold
View Inventory
Windows NT 6.3
Windows NT 6.3
Firefox 36.0
Firefox 36.0

Awards
« Reply #697 on: March 31, 2015, 02:44:36 pm »
Go Up Go Down

Quote:Posted by Saromines
My new DP2..

hi
i use 18f252 lcd for dp.how i adjust it?please any one guide me?

Linkback:

You are not allowed to view links.
Please Register or Login

http://www.thunting.com/smf/index.php/topic,28024.msg294335.html#msg294335




Logged
Offline RAMPI
Copper Member
*

Join Date: Jun, 2013
Thank you43

Activity
0%

Philippines
Posts: 87
Referrals: 0

877.00 Gold
View Inventory
Windows 7/Server 2008 R2
Windows 7/Server 2008 R2
Firefox 33.0
Firefox 33.0

Awards

Pulse Induction Metal detector
« Reply #698 on: March 31, 2015, 08:50:38 pm »
Go Up Go Down

Quote:Posted by ehsanajal
hi
i use 18f252 lcd for dp.how i adjust it?please any one guide me?


All info of DP2 is here in Geotech Forum

You are not allowed to view links.
Please Register or Login

http://www.geotech1.com/forums/showthread.php?8003-Delta-Pulse/page64&highlight=Delta+Pulse


For Delta Pulse 2+ calibration video

You are not allowed to view links.
Please Register or Login

http://www.youtube.com/watch?v=RGocN4qcjBQ


Linkback:

You are not allowed to view links.
Please Register or Login

http://www.thunting.com/smf/index.php/topic,28024.msg294345.html#msg294345




Logged
Offline ehsanajal
Copper Member
*

Join Date: Nov, 2010
Thank you1

Activity
0%

Afghanistan
Posts: 26
Referrals: 0

140.00 Gold
View Inventory
Windows NT 6.3
Windows NT 6.3
Firefox 37.0
Firefox 37.0

Awards
« Reply #699 on: April 13, 2015, 05:58:00 am »
Go Up Go Down

hello
i use in delta 2 mode of frequency , first 100hz another is 450hz that change by switch.
and i change in my board and now my DP have 10mks for sampling(or delay) . so i have many question:and i buy 18f252 from turkey and not demo
1-where is the position of the volumes on DP, like power Signal and..
2-i use 10mks for better search gold,so not problem for adjust 18f252?
3-i have 4 coils in these sizes ,30cm , 45*45cm , 60*60 cm, 1.1m*1.1m ,so if i set the discrimination ,it will work for all coil ?
4-when i switch the frequency not error on adjust of discrimination?
and many question.please help

Linkback:

You are not allowed to view links.
Please Register or Login

http://www.thunting.com/smf/index.php/topic,28024.msg295072.html#msg295072




Logged
Print
Pages:  1 ... 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 ... 91   Go Up
Jump to:  

Powered by SMF 1.1.19 | SMF © 2005, Simple Machines | Sitemap
Copyright THunting.com