TR: Detection is determined by the amount of Transmitted signal induced into the Receive Coil by a Target!
IB: Detection is determined by the Offset of Inductive Balance of two coils used in a Oscillator.
VLF: Detection is determined by Phase relationship of Transmit Coil and Receive Coil. The target will cause the Receive signal to be advanced or retarded in relationship to the transmit signal depending on target type. Mineral or Metal.